{"product_id":"dixsen-800-5a-split-core-current-transformer-class-0-5-burden-3-75-window-size-50-x-80mm-dbp-58-800-5-dbp-58800-5a","title":"Dixsen 800:5A Split Core Current Transformer Class 0.5 Burden 3.75 Window Size 50 x 80mm DBP-58 800:5 DBP-58800\/5A","description":"\u003ch1\u003eDixsen 800:5A Split Core Current Transformer Class 0.5 Burden 3.75VA Window Size 50 x 80mm DBP-58 – DBP-58800\/5A\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eDixsen DBP-58 800:5A Split Core Current Transformer\u003c\/strong\u003e is designed for electrical current measurement, monitoring, and metering applications in industrial and commercial electrical systems. With an \u003cstrong\u003e800A primary to 5A secondary current ratio\u003c\/strong\u003e, it allows high-current circuits to be monitored using compatible electrical meters, energy monitoring equipment, controllers, and protection devices.\u003c\/p\u003e\n\u003cp\u003eFeaturing a convenient \u003cstrong\u003esplit-core design\u003c\/strong\u003e, the DBP-58 can be installed around an existing electrical conductor without requiring the primary cable to be disconnected during installation. This makes it a practical solution for electrical panel upgrades, retrofit projects, energy monitoring, and maintenance applications where minimizing system interruption is important.\u003c\/p\u003e\n\u003cp\u003eThe transformer features a \u003cstrong\u003e50 x 80mm window size\u003c\/strong\u003e, providing an opening for appropriately sized cables or conductors. Its \u003cstrong\u003eClass 0.5 accuracy rating\u003c\/strong\u003e makes it suitable for applications requiring precise current measurement, while its specified \u003cstrong\u003e3.75VA burden\u003c\/strong\u003e supports compatible secondary measuring circuits within the transformer's rated operating conditions.\u003c\/p\u003e\n\u003ch3\u003eKey Features and Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Dixsen\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e DBP-58\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e DBP-58800\/5A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Ratio:\u003c\/strong\u003e 800:5A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrimary Current:\u003c\/strong\u003e 800A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSecondary Current:\u003c\/strong\u003e 5A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy Class:\u003c\/strong\u003e Class 0.5\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRated Burden:\u003c\/strong\u003e 3.75VA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWindow Size:\u003c\/strong\u003e 50 x 80mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eType:\u003c\/strong\u003e Split Core Current Transformer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e Split-core, non-intrusive installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e Electrical current measurement, monitoring, and metering\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSplit-Core Design for Convenient Installation\u003c\/h3\u003e\n\u003cp\u003eThe DBP-58 features a split-core construction that allows the transformer to open and fit around an existing electrical conductor. This design simplifies installation in existing electrical panels and distribution systems, helping reduce wiring modifications and installation downtime.\u003c\/p\u003e\n\u003ch3\u003e800:5A Current Transformation Ratio\u003c\/h3\u003e\n\u003cp\u003eWith an \u003cstrong\u003e800:5A ratio\u003c\/strong\u003e, the current transformer converts primary current into a proportional 5A secondary current for compatible measuring instruments. It is suitable for monitoring high-current electrical circuits in distribution boards, industrial facilities, and commercial power systems.\u003c\/p\u003e\n\u003ch3\u003eClass 0.5 Measurement Accuracy\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eClass 0.5 accuracy rating\u003c\/strong\u003e makes this current transformer suitable for applications that require precise and dependable current measurement. When properly installed and connected to compatible equipment within its rated burden, it can support electrical monitoring, metering, and power management activities.\u003c\/p\u003e\n\u003ch3\u003eCommon Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial electrical panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCommercial power distribution systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical distribution boards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnergy and power monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEquipment load monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical metering systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower management applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical maintenance and testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExisting electrical system upgrades\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-current circuit monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe \u003cstrong\u003eDixsen DBP-58 800:5A Split Core Current Transformer\u003c\/strong\u003e combines an 800:5A current ratio, Class 0.5 accuracy, 3.75VA rated burden, and 50 x 80mm window size in a convenient split-core design. It is a practical choice for high-current electrical measurement and monitoring applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAvailable in Electx Electrical Supply.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Dixsen","offers":[{"title":"Default Title","offer_id":41819637055563,"sku":"DBP-58800\/5A","price":9225.0,"currency_code":"PHP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0616\/9732\/7179\/files\/Dixsen8005ASplitCoreCurrentTransformerClass0.5Burden2.5WindowSize50x80mmDBP-588005ElectxElectricalSupply_2.jpg?v=1760101322","url":"https:\/\/www.electxelectricalsupply.com\/products\/dixsen-800-5a-split-core-current-transformer-class-0-5-burden-3-75-window-size-50-x-80mm-dbp-58-800-5-dbp-58800-5a","provider":"Electx Electrical Supply","version":"1.0","type":"link"}