{"product_id":"dixsen-current-transformer-mr-85-800-5a-donut-type-class-0-5-mr-85-800-5a","title":"Dixsen Current Transformer MR-85 800:5A Donut Type Class 0.5 MR-85 800\/5A","description":"\u003ch1\u003eDixsen MR-85 800:5A Donut Type Current Transformer Class 0.5\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eDixsen MR-85 800:5A Donut Type Current Transformer\u003c\/strong\u003e is an electrical measuring component designed to convert high primary current into a standardized 5A secondary current for use with compatible electrical measuring instruments and monitoring systems. With an \u003cstrong\u003e800:5A current ratio\u003c\/strong\u003e, this current transformer is suitable for electrical installations that require current measurement and monitoring in power distribution panels, industrial equipment, and other compatible electrical systems.\u003c\/p\u003e\n\u003cp\u003eDesigned with a donut-type construction, the Dixsen MR-85 features a central opening through which a suitable cable, conductor, or busbar passes to measure current without directly connecting the primary conductor to the CT secondary circuit. Its \u003cstrong\u003eClass 0.5 accuracy rating\u003c\/strong\u003e makes it suitable for applications requiring accurate current measurement when operated within the manufacturer's specified conditions.\u003c\/p\u003e\n\u003cp\u003eThe Dixsen MR-85 800:5A Current Transformer can be integrated into compatible metering and electrical monitoring setups. It provides a practical solution for installations that use instruments with a standard 5A current transformer input.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Dixsen\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e MR-85\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Donut Type Current Transformer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Ratio:\u003c\/strong\u003e 800:5A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrimary Current:\u003c\/strong\u003e 800A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSecondary Current:\u003c\/strong\u003e 5A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy Class:\u003c\/strong\u003e Class 0.5\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDesign:\u003c\/strong\u003e Ring-shaped or donut-type construction\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e Current measurement and electrical monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Benefits\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eClass 0.5 Accuracy\u003c\/strong\u003e\u003cbr\u003eDesigned for current measurement applications that require good measurement accuracy, subject to the CT's rated operating conditions and connected burden.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e800:5A Current Ratio\u003c\/strong\u003e\u003cbr\u003eConverts a primary current of up to the specified 800A rating into a proportional secondary current suitable for compatible 5A-input meters and instruments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDonut-Type Design\u003c\/strong\u003e\u003cbr\u003eThe ring-shaped design allows a compatible conductor or busbar to pass through the center opening. Confirm the actual window dimensions and conductor clearance before installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSuitable for Electrical Monitoring\u003c\/strong\u003e\u003cbr\u003eCan be used as part of compatible current measurement systems in electrical distribution panels, industrial facilities, and power monitoring installations.\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eThe Dixsen MR-85 800:5A Current Transformer may be used in:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical distribution panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial power systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAmmeter and current meter installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical load monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower monitoring systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible energy metering setups\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCommercial and industrial electrical installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eDixsen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMR-85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCT Type\u003c\/td\u003e\n\u003ctd\u003eDonut Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Current\u003c\/td\u003e\n\u003ctd\u003e800A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Current\u003c\/td\u003e\n\u003ctd\u003e5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Ratio\u003c\/td\u003e\n\u003ctd\u003e800:5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy Class\u003c\/td\u003e\n\u003ctd\u003eClass 0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWindow Dimensions\u003c\/td\u003e\n\u003ctd\u003eConfirm with product nameplate or manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eInstallation and Safety\u003c\/h2\u003e\n\u003cp\u003eBefore installation, verify the current ratio, accuracy class, rated burden, physical dimensions, and compatibility with the connected meter or monitoring equipment. Installation should be carried out by a qualified electrician or electrical professional.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety reminder:\u003c\/strong\u003e Never leave the secondary circuit of an energized current transformer open-circuited. Before disconnecting a connected meter or instrument, ensure the CT secondary is safely shorted using an approved method.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eDixsen MR-85 800:5A Donut Type Current Transformer\u003c\/strong\u003e is a practical option for current measurement and monitoring in compatible electrical systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAvailable in Electx Electrical Supply.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003ehttps:\/\/youtube.com\/shorts\/IgmgiVryMS4\u003cbr\u003e\u003c\/p\u003e","brand":"Dixsen","offers":[{"title":"Default Title","offer_id":42165029797963,"sku":"MR-85 800\/5A","price":1600.0,"currency_code":"PHP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0616\/9732\/7179\/files\/Dixsen_Current_Transformer_MR-85_800_5A_Donut_Type_Class_0.5_MR-85_800_5A_I_Electx_Electrical_Supply.jpg?v=1791596684","url":"https:\/\/www.electxelectricalsupply.com\/products\/dixsen-current-transformer-mr-85-800-5a-donut-type-class-0-5-mr-85-800-5a","provider":"Electx Electrical Supply","version":"1.0","type":"link"}