{"product_id":"himel-63a-4p-n-30ma-6-kaic-220v-residual-current-operated-circuit-breaker-rcbo-with-overload-protection-hdb3le4c-copy-3","title":"Himel 20A 4P+N 30mA 6 KAIC 220V Residual Current Operated Circuit Breaker RCBO with Overload Protection HDB3LE4C20","description":"\u003cp data-path-to-node=\"0\"\u003eThe Himel HDB3LE4C20 is a 4-pole Residual Current Operated Circuit Breaker with Overload Protection (RCBO), engineered to provide comprehensive ground leakage, thermal overload, and short-circuit protection for three-phase electrical circuits.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"1\"\u003eCore Features \u0026amp; Protection\u003c\/h3\u003e\n\u003cul data-path-to-node=\"2\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,0,0\"\u003e\u003cb data-path-to-node=\"2,0,0\" data-index-in-node=\"0\"\u003eIntegrated Circuit Defense:\u003c\/b\u003e Unifies residual current protection (RCD) and thermal-magnetic overcurrent protection (MCB) into a single compact DIN-rail module, maximizing panelboard space and streamlining installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,1,0\"\u003e\u003cb data-path-to-node=\"2,1,0\" data-index-in-node=\"0\"\u003e30mA Shock \u0026amp; Fire Safeguard:\u003c\/b\u003e Operates with a high-sensitivity 30mA residual tripping threshold (\u003cspan class=\"math-inline\" data-math=\"\\Delta n = 30\\text{ mA}\" data-index-in-node=\"96\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003eΔ\u003c\/span\u003e\u003cspan class=\"mord mathnormal\"\u003en\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003cspan class=\"mrel\"\u003e=\u003c\/span\u003e\u003cspan class=\"mspace\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e30\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003e mA\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e) to instantly disconnect power upon sensing earth leakage currents, protecting personnel against electric shock hazards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,2,0\"\u003e\u003cb data-path-to-node=\"2,2,0\" data-index-in-node=\"0\"\u003eFull 4-Pole (4P) Protection:\u003c\/b\u003e Features dedicated overcurrent and short-circuit monitoring across all four poles (L1, L2, L3, and Neutral), delivering full isolation and safety for balanced or unbalanced 3-phase, 4-wire distribution networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,3,0\"\u003e\u003cb data-path-to-node=\"2,3,0\" data-index-in-node=\"0\"\u003eType C Tripping Curve:\u003c\/b\u003e Designed with a C-curve response to handle light inductive inrush currents commonly associated with commercial power circuits, small motors, and HVAC systems without nuisance tripping.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"3\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"4\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,0,0\"\u003e\u003cb data-path-to-node=\"4,0,0\" data-index-in-node=\"0\"\u003eBrand \u0026amp; Series:\u003c\/b\u003e Himel (HDB3LE Series)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,1,0\"\u003e\u003cb data-path-to-node=\"4,1,0\" data-index-in-node=\"0\"\u003eModel \/ Part Number:\u003c\/b\u003e HDB3LE4C20\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,2,0\"\u003e\u003cb data-path-to-node=\"4,2,0\" data-index-in-node=\"0\"\u003eRated Current (\u003cspan class=\"math-inline\" data-math=\"I_n\" data-index-in-node=\"15\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e\u003cspan class=\"mord mathnormal\"\u003eI\u003c\/span\u003e\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t vlist-t2\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mathnormal mtight\"\u003en\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-s\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e):\u003c\/b\u003e 20 Amperes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,3,0\"\u003e\u003cb data-path-to-node=\"4,3,0\" data-index-in-node=\"0\"\u003eNumber of Poles:\u003c\/b\u003e 4P (4 Protected Poles)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,4,0\"\u003e\u003cb data-path-to-node=\"4,4,0\" data-index-in-node=\"0\"\u003eResidual Current Sensitivity (\u003cspan class=\"math-inline\" data-math=\"\\Delta n\" data-index-in-node=\"30\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003eΔ\u003c\/span\u003e\u003cspan class=\"mord mathnormal\"\u003en\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e):\u003c\/b\u003e 30mA (Instantaneous)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,5,0\"\u003e\u003cb data-path-to-node=\"4,5,0\" data-index-in-node=\"0\"\u003eRated Breaking Capacity (\u003cspan class=\"math-inline\" data-math=\"I_{cn}\" data-index-in-node=\"25\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e\u003cspan class=\"mord mathnormal\"\u003eI\u003c\/span\u003e\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t vlist-t2\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mord mtight\"\u003e\u003cspan class=\"mord mathnormal mtight\"\u003ec\u003c\/span\u003e\u003cspan class=\"mord mathnormal mtight\"\u003en\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-s\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e):\u003c\/b\u003e 6 kA (6000A)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,6,0\"\u003e\u003cb data-path-to-node=\"4,6,0\" data-index-in-node=\"0\"\u003eOperating Voltage:\u003c\/b\u003e 220V \/ 400V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,7,0\"\u003e\u003cb data-path-to-node=\"4,7,0\" data-index-in-node=\"0\"\u003eMounting Standard:\u003c\/b\u003e 35mm DIN Rail Mount\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,8,0\"\u003e\u003cb data-path-to-node=\"4,8,0\" data-index-in-node=\"0\"\u003eStandards Compliance:\u003c\/b\u003e IEC\/EN 61009-1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"5\"\u003ePrimary Applications\u003c\/h3\u003e\n\u003cp data-path-to-node=\"6\"\u003eIdeally suited for commercial office distribution sub-panels, light industrial equipment, and 3-phase circuits requiring up to 20A continuous load capacity alongside reliable ground fault and overcurrent protection.\u003c\/p\u003e\n\u003cp data-path-to-node=\"8\"\u003eAvailable at Electx Electrical Supply.\u003c\/p\u003e","brand":"Himel","offers":[{"title":"Default Title","offer_id":42940482453579,"sku":"HDB3LE4C20","price":3250.0,"currency_code":"PHP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0616\/9732\/7179\/files\/Himel20A4P_N30mA6KAIC220VResidualCurrentOperatedCircuitBreakerRCBOwithOverloadProtectionHDB3LE3C20.jpg?v=1784878028","url":"https:\/\/www.electxelectricalsupply.com\/products\/himel-63a-4p-n-30ma-6-kaic-220v-residual-current-operated-circuit-breaker-rcbo-with-overload-protection-hdb3le4c-copy-3","provider":"Electx Electrical Supply","version":"1.0","type":"link"}