{"product_id":"surer-no-172-nema-6-50r-power-outletflush-mount-50a-125-250v-2p-3-wire-grounding-receptacle","title":"Surer No.172 NEMA 6-50R Power Outlet, Flush Mount (50A 125\/250V) 2P 3-Wire Grounding Receptacle","description":"\u003ch2\u003eSurer No.172 NEMA 6-50R Power Outlet, Flush Mount 50A 125\/250V 2P 3-Wire Grounding Receptacle\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSurer No.172 NEMA 6-50R Power Outlet\u003c\/strong\u003e is a heavy-duty \u003cstrong\u003eflush-mount receptacle\u003c\/strong\u003e designed for compatible high-current electrical installations requiring a \u003cstrong\u003e50A, 125\/250V\u003c\/strong\u003e power connection. Featuring a \u003cstrong\u003eNEMA 6-50R configuration\u003c\/strong\u003e, this receptacle provides a \u003cstrong\u003e2-pole, 3-wire grounding\u003c\/strong\u003e connection for equipment designed to use this specific receptacle type.\u003c\/p\u003e\n\u003cp\u003eIts flush-mount design allows the outlet to be installed neatly into a suitable electrical box or enclosure, creating a secure and organized finished installation. The Surer No.172 is a practical choice for workshops, garages, commercial facilities, industrial environments, equipment areas, and other applications requiring a dedicated high-current receptacle.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Surer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e No.172\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Configuration:\u003c\/strong\u003e 6-50R\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Power Outlet \/ Receptacle\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Type:\u003c\/strong\u003e Flush Mount\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Rating:\u003c\/strong\u003e 50A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Rating:\u003c\/strong\u003e 125\/250V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration:\u003c\/strong\u003e 2P, 3-Wire\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e Grounding Receptacle\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHeavy-duty electrical application\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuitable for compatible high-current equipment\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePractical design for permanent installations\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNEMA 6-50R Configuration\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eNEMA 6-50R\u003c\/strong\u003e configuration is intended for compatible electrical equipment requiring a 50-ampere receptacle with the corresponding plug configuration. The Surer No.172 uses a \u003cstrong\u003e2-pole, 3-wire grounding arrangement\u003c\/strong\u003e, providing the appropriate connection for compatible electrical systems.\u003c\/p\u003e\n\u003cp\u003eBecause NEMA receptacles have specific configurations, users should always confirm that the equipment plug, circuit, wiring, and receptacle are compatible before installation. A different NEMA configuration should not be substituted simply because it has the same amperage or voltage rating.\u003c\/p\u003e\n\u003ch3\u003e50A 125\/250V Rating\u003c\/h3\u003e\n\u003cp\u003eThe Surer No.172 is rated at \u003cstrong\u003e50A and 125\/250V\u003c\/strong\u003e, making it suitable for compatible high-current electrical applications within its specified rating.\u003c\/p\u003e\n\u003cp\u003eWhen planning an installation, the complete circuit should be appropriately rated for the intended load. This includes the conductors, circuit breaker, electrical box, receptacle, plug, and connected equipment. Proper circuit protection is essential for safe operation.\u003c\/p\u003e\n\u003ch3\u003e2P 3-Wire Grounding Design\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e2-pole, 3-wire grounding configuration\u003c\/strong\u003e provides two current-carrying conductors and a grounding connection for compatible installations. The grounding connection is an important safety feature that helps provide a path for fault current when correctly connected to the electrical system's grounding network.\u003c\/p\u003e\n\u003cp\u003eProper wiring and grounding must follow the requirements of the applicable electrical code. The receptacle should never be installed without verifying the existing circuit configuration.\u003c\/p\u003e\n\u003ch3\u003eFlush-Mount Construction\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eflush-mount design\u003c\/strong\u003e allows the receptacle to sit neatly within a compatible electrical box or enclosure. This provides a clean appearance and helps keep the outlet securely positioned for regular equipment connection and disconnection.\u003c\/p\u003e\n\u003cp\u003eIt is well suited for permanent installations where a dedicated high-current outlet is required and where a surface-mounted receptacle is not preferred.\u003c\/p\u003e\n\u003ch3\u003eVersatile Applications\u003c\/h3\u003e\n\u003cp\u003eThe Surer No.172 can be used in compatible electrical applications including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWorkshops and work areas\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGarages and service areas\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCommercial facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-current equipment installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDedicated electrical circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEquipment maintenance and replacement projects\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUtility areas\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOther applications requiring a NEMA 6-50R receptacle\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSurer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNo.172\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceptacle Type\u003c\/td\u003e\n\u003ctd\u003eNEMA 6-50R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePower Outlet \/ Receptacle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eFlush Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e50A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e125\/250V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003e2P, 3-Wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrounding\u003c\/td\u003e\n\u003ctd\u003eGrounding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eCompatible high-current electrical installations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWhy Choose Surer No.172?\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSurer No.172 NEMA 6-50R Power Outlet\u003c\/strong\u003e is a practical solution for installations requiring a \u003cstrong\u003e50A, 125\/250V, 2P 3-wire grounding receptacle\u003c\/strong\u003e. Its flush-mount construction provides a neat and secure installation, while the NEMA 6-50R configuration allows connection of compatible high-current equipment.\u003c\/p\u003e\n\u003cp\u003eWhether used in a \u003cstrong\u003eworkshop, garage, commercial facility, industrial area, or equipment installation\u003c\/strong\u003e, the Surer No.172 provides a dependable power connection for applications specifically designed around its electrical configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Always verify the equipment plug, circuit voltage, amperage, wiring, breaker, electrical box, and grounding system before installation. Use the receptacle only within its specified electrical rating. Installation should be performed by a qualified electrician and in accordance with applicable electrical codes and safety requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAvailable at Electx Electrical Supply\u003c\/strong\u003e — your source for Surer electrical receptacles, power outlets, and electrical supplies.\u003c\/p\u003e","brand":"Surer","offers":[{"title":"Default Title","offer_id":42294189621323,"sku":"No.172","price":940.0,"currency_code":"PHP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0616\/9732\/7179\/files\/Surer_No.172_NEMA_6-50R_Power_Outlet_Flush_Mount_50A_125_250V_2P_3-Wire_Grounding_Receptacle_I_Electx_Electrical_Supply.jpg?v=1789362283","url":"https:\/\/www.electxelectricalsupply.com\/products\/surer-no-172-nema-6-50r-power-outletflush-mount-50a-125-250v-2p-3-wire-grounding-receptacle","provider":"Electx Electrical Supply","version":"1.0","type":"link"}